| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|
| #Q001 | administrative | unknown | mandatory | National Capital Act Approval | drinking water | Since this project involves NCC federal land, the project requires an approval under the National Capital Act. | Project involves NCC federal land | high |
| #Q002 | administrative | unknown | mandatory | Canadian Navigable Waters Act Authorization | drinking water | This project also involves Transport Canada, as the new pipe and temporary dock require an authorization under the Canadian Navigable Waters Act. | New pipe and temporary dock construction | high |
| #Q003 | operational | operational | mandatory | In-water Works Phasing and Timing | drinking water, aquatic life | In-water works are permitted by Fisheries and Oceans Canada (DFO) from July 15 to March 31 and will occur in two (2) phases to comply with this requirement. | In-water works | high |
| #Q004 | operational | unknown | mandatory | Implementation of Mitigation Measures | other | Other mitigation measures to safeguard the local environment and socio-economic conditions will be implemented as determined by the environmental review of the project and applicable laws and regulations applicable to the project. | high | |
| #Q005 | administrative | unknown | mandatory | Authority Responsibility for Project Assessment | drinking water, other | The listed authorities are responsible for the project assessment. | Non-designated project on federal lands or outside Canada | high |
| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Limit Type | Limit Value | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|---|---|
| #P001 | design | operational | mandatory | Intake pipe water depth | drinking water | requirement | 15-17 m | To mitigate against frazil ice, the proposed intake pipe will extend further offshore, in a deeper part of the Ottawa River, with a water depth between 15 and 17 m. | high | |
| #P002 | design | operational | mandatory | Dock footprint | drinking water | requirement | <= 175 m2 | The construction of a temporary dock and temporary staging area are required to support the in-water works... The dock footprint will be at most 175 m2 | high | |
| #P003 | design | operational | mandatory | Temporary construction easement | drinking water | requirement | 261 m2 | and the temporary construction easement will be 261 m2. | medium | |
| #P004 | design | operational | mandatory | Staging area | drinking water | requirement | 5500 m2 | The staging area will be on land, adjacent to the dock, and will have an area of approximately 5500 m2. | medium | |
| #P005 | operational | operational | mandatory | Project duration | drinking water | requirement | 2 years | The project will take place over 2 years with a potential start in 2024. | Potential start in 2024 | high |
| #P006 | operational | operational | mandatory | Construction phases | drinking water | requirement | 2 phases | will occur in two (2) phases to comply with this requirement. | To comply with Fisheries and Oceans Canada (DFO) permitted window | high |
| #P007 | operational | operational | mandatory | In-water work permitted window | aquatic life | requirement | July 15 - March 31 date range | In-water works are permitted by Fisheries and Oceans Canada (DFO) from July 15 to March 31 | Permitted by Fisheries and Oceans Canada (DFO) | high |
| Req ID | Category | Name | Context | Confidence |
|---|---|---|---|---|
| #D001 | WPP | Water Purification Plant | high | |
| #D002 | NCC | National Capital Commission | high | |
| #D003 | DFO | Fisheries and Oceans Canada | high | |
| #D004 | frazil ice | slush and ice | medium | |
| #D005 | SSR | Southern Structures Renewal | high | |
| #D006 | DES | district energy system | high | |
| #D007 | MGEC | Modernized Gatineau Energy Centre | high | |
| #D008 | ONEC | Ottawa New Edinburgh Club | high | |
| #D009 | AEP | Advanced Electronics and Photonics | high | |
| #D010 | TC NCA | TerraCanada National Capital Area | high | |
| #D011 | RSS | Regulatory and Security Sciences | high | |
| #D012 | TPOF | Technical and Protective Operations Facility | high | |
| #D013 | DRDC | Defence Research Development Canada | high | |
| #D014 | ORC | Ottawa Research Centre | high | |
| #D015 | MBD | Modified Design Build | high | |
| #D016 | LCD | Letter Carrier Depot | high | |
| #D017 | UCLG | United Counties of Leeds and Grenville | high | |
| #D018 | MVTC | Motor Vehicle Test Centre | high | |
| #D019 | VOR | Very High Frequency Omni-Direction Range | high | |
| #D020 | HVAC | Heating, Ventilation, and Air Conditioning | high | |
| #D021 | EPC | Energy Performance Contract | high | |
| #D022 | CJIM | Combined Joint Intelligence Modernization | high | |
| #D023 | REM | Réseau express métropolitain | high | |
| #D024 | GSE | Ground Service Equipment | high | |
| #D025 | KLCC | Kenhtè:ke Language and Cultural Centre | high | |
| #D026 | RPAS | Remotely Piloted Aircraft Systems | high | |
| #D027 | CFB | Canadian Forces Base | high | |
| #D028 | CFS | Canadian Forces Station | high | |
| #D029 | CFSMI | Canadian Forces School of Military Intelligence | high | |
| #D030 | CFSCE | Canadian Forces School of Communications and Electronics | high | |
| #D031 | KIH | Kingston Inner Harbour | high | |
| #D032 | QED | Queen Elizabeth Driveway | high | |
| #D033 | CBD | Colonel By Drive | high | |
| #D034 | NRC | National Research Council | high | |
| #D035 | MBQ | Mohawks of the Bay of Quinte | high | |
| #D036 | SNIC | Heavy Equipment | high |