| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|
| #Q001 | administrative | unknown | mandatory | Project Assessment Responsibility | other | The listed authorities are responsible for the project assessment. | This is a non-designated project on federal lands or outside Canada. | high |
| #Q002 | design | operational | mandatory | Outfall Pipe Placement | other | The outfall pipe will be placed below the low water mark. | high | |
| #Q003 | design | operational | mandatory | Pipeline Protection and Screening | aquatic life, other | Intake and outfall pipelines will be protected from damage in the water with specifically designed structures, and there will be screens to prevent intake of debris and marine biota. | high | |
| #Q004 | design | operational | mandatory | Pipeline Marking | other | Both pipelines will be marked to ensure harbour users are aware of their location. | high | |
| #Q005 | operational | operational | mandatory | Seawater Return Discharge Specifications | other | The seawater return pipeline will discharge to Halifax Harbour via an outlet pipe. The water will be returned to the harbour at a temperature approximately two degrees higher than when withdrawn and at a higher depth then where it was removed, ideally where ambient water temperature is in the same range as the outfall temperature. | high |
| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Limit Type | Limit Value | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|---|---|
| #R001 | physical | operational | mandatory | Seawater Return Temperature Differential | aquatic life | requirement | ~ 2 degrees | The water will be returned to the harbour at a temperature approximately two degrees higher than when withdrawn and at a higher depth then where it was removed, ideally where ambient water temperature is in the same range as the outfall temperature. | Returned to the harbour via an outlet pipe | high |
| Req ID | Category | Name | Context | Confidence |
|---|---|---|---|---|
| #D001 | HRM | Halifax Regional Municipality | high | |
| #D002 | DND | Department of National Defence | high | |
| #D003 | NS | Nova Scotia | high | |
| #D004 | CFB | Canadian Forces Base | high | |
| #D005 | BIO | Bedford Institute of Oceanography | high | |
| #D006 | FIMS | Facility for Intelligent Marine Systems | high | |
| #D007 | FLR | Fish Lab Renovations | high | |
| #D008 | LNAPL | Light Non-Aqueous Phase Liquid | high | |
| #D009 | CFAD | Canadian Forces Ammunition Depot | high | |
| #D010 | RPAS | Remotely Piloted Aircraft System | high | |
| #D011 | RHUs | residential housing units | high | |
| #D012 | INFERNO | Instructional Natural Fire Environment for Readiness in Operations | high | |
| #D013 | VOR | Very High Frequency Omni-directional Range | high | |
| #D014 | NRS | Naval Radio Station | high | |
| #D015 | SCH | Small Craft Harbour | high | |
| #D016 | ASEC | Atlantic Science Enterprise Centre | high | |
| #D017 | LCD | Letter Carrier Depot | high | |
| #D018 | MPP | Mail Processing Plant | high | |
| #D019 | PCD | Pictou County Detachment | high | |
| #D020 | X-Area | Explosive Storage Area | high |