| #R001 | chemical | reporting | mandatory | Method detection limit (MDL) for PFOA and PFOS | drinking water | requirement | 20 ng/L | Municipalities required to test raw and treated drinking water for the presence of PFOA and PFOS | As of 2019 | high |
| #R002 | chemical | reporting | mandatory | Minimum reporting level (MRL) for PFOA | drinking water | requirement | 20 ng/L | US EPA Third Unregulated Contaminant Monitoring Rule (UCMR3) | Monitoring between 2013 and 2015 | high |
| #R003 | chemical | reporting | mandatory | Minimum reporting level (MRL) for PFOS | drinking water | requirement | 40 ng/L | US EPA Third Unregulated Contaminant Monitoring Rule (UCMR3) | Monitoring between 2013 and 2015 | high |
| #R004 | chemical | reporting | mandatory | Minimum reporting level (MRL) for PFBS | drinking water | requirement | 90 ng/L | US EPA Third Unregulated Contaminant Monitoring Rule (UCMR3) | Monitoring between 2013 and 2015 | high |
| #R005 | chemical | reporting | guidance | Method detection limit (MDL) for PFOA and PFOS (Saskatchewan) | drinking water | requirement | 2 ng/L | Saskatchewan Water Security Agency drinking water sampling | Treated drinking water samples from 7 communities in 2018–2019 | high |
| #R006 | chemical | reporting | guidance | Method detection limits (MDLs) range for 14 PFAS (Ontario) | drinking water | requirement | 0.5 to 1 ng/L | Ontario Ministry of the Environment, Conservation and Parks drinking water system measurements | 25 drinking water systems in Ontario between 2012 and 2016 | high |
| #R007 | chemical | reporting | guidance | Detection limit range for treated water (Quebec) | drinking water | requirement | 0.3 to 5 ng/L | Quebec Ministère de l'Environnement et de la Lutte contre les changements climatiques (MELCC) sampling | 41 drinking water treatment systems sampled between 2016 and 2021 | high |
| #R008 | chemical | reporting | mandatory | Minimum reporting levels (MRLs) range for 6 PFAS (US EPA) | drinking water | requirement | 10 to 90 ng/L | US EPA Third Unregulated Contaminant Monitoring Rule (UCMR3) | Monitoring of 6 PFAS (PFHpA, PFOA, PFNA, PFBS, PFHxS and PFOS) between 2013 and 2015 | high |
| #R009 | chemical | reporting | guidance | Detection limit range for raw water (Quebec) | drinking water | requirement | 0.5 to 5 ng/L | Quebec's Ministère de l'Environnement et de la Lutte contre les changements climatiques (MELCC) sampling of 41 systems | Raw water samples tested for 18 PFAS between 2016 and 2021 | high |
| #R010 | chemical | reporting | guidance | Detection limits range for national freshwater study | drinking water | requirement | 0.4 to 1.6 ng/L | Study examining the presence of PFAS in freshwater at 29 sites across Canada | Sampling from 2013 to 2020 for 13 different PFAS | high |
| #R011 | chemical | reporting | guidance | Limits of detection for Canadian tap water study | drinking water | requirement | 0.01 to 0.08 ng/L | Study of drinking water sourced from 19 sites around Lake Ontario, the St. Lawrence River, and other Canadian lakes/rivers | Detection limits specified for tap water analysis | high |