| #P001 | physical | unknown | mandatory | pH | wastewater | requirement | 6.5 to 9.0 pH | Effluent discharge to surface fresh or marine waters from a concrete or concrete products facility | Passes through an effluent treatment system inspected monthly | high |
| #P002 | physical | unknown | mandatory | suspended solids | wastewater | MAC | 75 mg/L | Effluent discharge to surface fresh or marine waters from a concrete or concrete products facility | Passes through an effluent treatment system inspected monthly | high |
| #P003 | chemical | unknown | mandatory | total extractable hydrocarbon | wastewater | MAC | 15 mg/L | Effluent discharge to surface fresh or marine waters from a concrete or concrete products facility | Passes through an effluent treatment system inspected monthly | high |
| #P004 | unknown | unknown | mandatory | acutely toxic to rainbow trout | wastewater | requirement | 100 % concentration | Effluent discharge to surface fresh or marine waters from a concrete or concrete products facility | Must be non-acutely toxic | high |
| #P005 | operational | operational | mandatory | Effluent treatment system inspection frequency | wastewater | requirement | 1 per month | Effluent treatment system verification to ensure it is in good working order | Applies when discharging to surface fresh or marine waters | high |
| #P006 | operational | operational | mandatory | Process and facility runoff sampling frequency | wastewater | requirement | >= 1 per month | Sampling and analysis of process and facility runoff | Applies to process and facility runoff | high |
| #P007 | operational | reporting | mandatory | Record retention period | wastewater | requirement | >= 5 years | Maintenance of sampling, analysis, and inspection records | | high |
| #P008 | physical | treatment | mandatory | Maximum suspended solids | wastewater | MAC | <= 75 mg/L | Effluent discharge to surface fresh or marine waters from a concrete facility | After passing through effluent treatment system | high |
| #P009 | chemical | treatment | mandatory | Maximum total extractable hydrocarbon | wastewater | MAC | <= 15 mg/L | Effluent discharge to surface fresh or marine waters from a concrete facility | After passing through effluent treatment system | high |
| #P010 | operational | reporting | mandatory | Administrative Penalty (Record Keeping) | wastewater | requirement | <= 10000 $ | Failure to maintain sampling, analysis, or inspection records | Based on minimum five-year record maintenance requirement | high |
| #P011 | operational | operational | mandatory | Administrative Penalty (General Compliance) | wastewater | requirement | <= 40000 $ | Failure to meet any other individual requirements of the code | | high |
| #P012 | unknown | operational | mandatory | Rainbow trout bioassay duration | aquatic life | requirement | 96 hour | Effluent toxicity testing for discharge to surface waters | 100% concentration | high |